Default Re: Monitoring STMS disk multi pathing

In article <1105858730.800815.58470@z14g2000cwz.googlegroups. com>,
<co4770@yahoo.com> wrote:
>
>
>Hi,
>
>I have STMS enabled for mutipathing using FC-AL disks and X6727A HBA.
>Disks are mirrored using Traffic manager paths
>
>Can I see both paths working and it's performance.Appreciate some tips.


The command 'luxadm probe' will show the virtual paths. If you do a
'luxadm display {pathname}' it will show the underlying physical paths.

The performance is often measured on the disk array of fibre channel switches.
In solaris 'iostat -tcx 5' is a nice tool, however I don't think it will show
traffic on the physical paths.

You could always dispable one path and ee if that impacts your application
performance.

/Regards
Fredrik


--