Thread: Re: Help please
View Single Post

   
  #4 (permalink)  
Old 02-15-2008, 10:06 AM
Mike Brown
 
Posts: n/a
Default Re: Help please

Fester wrote:
>
> "Fester" <fester@nospamtagmx.co.uk> wrote in message
> news:bemk3u$hb0$1@newsreaderm1.core.theplanet.net. ..
> >
> > "Mike Brown" <mike@tkg.ca> wrote in message

> news:3F0ECAA3.4069C2FA@tkg.ca...
> > > Fester wrote:
> > > >
> > > > I'm running SCO 5.0.5 on a Dell Poweredge 4600 with 4 drives. Two
> > > > containers, two drives per container. Using the Dell Percraid 3DC. I'm
> > > > running the "amird" drivers which seem to work well except when i want

> > to
> > > > add the second container i can see no way to do this.
> > > >
> > > > Yes i've tried every combination of mkdev hd i can think of and

> sconf -v
> > > > doesn't show anything more than i can see already.
> > > >
> > > > Has anyone else mananged to get this working???
> > > >
> > > > I'm pulling out what's left my hair here
> > > >
> > > > Cheers.
> > > >
> > > > Patrick
> > >
> > > I have not worked with the 3DC, but I remember some of the older raid
> > > controllers based on the AMI board set the second volume ( container )
> > > as LUN1, where the first unit was LUN0. So it was
> > >
> > > amird controller 0 bus 0 id 0 lun 0
> > > amird controller 0 bus 0 id 0 lun 1
> > >
> > > Mike
> > >
> > > --
> > > Michael Brown
> > >
> > > The Kingsway Group

> >
> > Yep i'd read that too ... but it still seems to have issues picking the
> > second container up. I installed 2k server this morning to check it wasn't
> > something i'd forgotten to do with the drives and that worked. I've also
> > tried the controller card in H20 mode and mass storage mode.
> >
> > Any other suggestions gratefully recieved at this point in time
> >
> > Cheers.
> >
> > Patrick.
> >
> >

> Weird, changed drives back to I20 mode.
>
> used mkdev hd 0 SCSI-0 1 amird 0
>
> Rebooted and repeated command and lo and behold there's my new disk!!
>
> Just got to mount and format it now


Thanks for posting the info back.

I did not know that drives have I2O mode, did you mean the raid controller?

The command would be consistent with the second container having a LUN of 1,

mkdev hd ID number lun ha [ bus ]

where the SCSI ID is 0
the controller is SCSI-0
LUN is 1
the host adapter is amird
and on bus 0

Did you try this command before loading WIN2K and had it fail, but it worked
after the 2K load?

Mike

--
Michael Brown