vBulletin Search Engine Optimization
| |||||||
| Register | FAQ | Members List | Calendar | Search | Today's Posts | Mark Forums Read |
| ||||
| This is my first 3xxx drive. Sun came and replaced the failed drive and it shows as scanned in the event log. No rebuild in progress. The replaced drive shows as: 2(3) 27 68.37GB 200MB NONE USED SEAGATE ST373453FSUN72G 0449 S/N WWNN 20000011C66B22CB The array is configured as RAID 1. How do I get this to do a rebuild? Sun support has no idea!!! LD LD-ID Size Assigned Type Disks Spare Failed Status ------------------------------------------------------------------------ ld0 193BBE06 408.70GB Primary RAID1 11 0 1 Degraded Write-Policy Default StripeSize 128KB * disk-array init-verify: disabled rebuild-verify: disabled normal-verify: disabled rebuild-priority: low Thanks Gary Quiring |
| |||
| gquiring@gmail.com wrote: > This is my first 3xxx drive. Sun came and replaced the failed drive > and it shows as scanned in the event log. No rebuild in progress. The > replaced drive shows as: > > 2(3) 27 68.37GB 200MB NONE USED SEAGATE ST373453FSUN72G > 0449 > S/N > WWNN 20000011C66B22CB > > The array is configured as RAID 1. How do I get this to do a rebuild? Mark the drive as a hot spare. Within a few seconds the array will automatically start the rebuild. Scott |