This is a discussion on Close a resdata event? within the HP-UX Operating System forums, part of the Unix Operating Systems category; --> Hello all, so I've an L2000 server with HP-UX 11.... some days ago I got a temperature problem. System ...
| |||||||
| FAQ | Members List | Calendar | Search | Today's Posts | Mark Forums Read |
| ||||
| Hello all, so I've an L2000 server with HP-UX 11.... some days ago I got a temperature problem. System shown me: #:/opt/resmon/bin/resdata -R 200802305 -r "/system/events/core_hw/core_hw" -a CURRENT MONITOR DATA: Event Time..........: Sun Apr 2 22:44:44 2006 Severity............: CRITICAL Monitor.............: dm_core_hw Event #.............: 33 System..............: mysystem.my Summary: Processor cabinet intake temperature is too hot Description of Error: The system intake temperature is too high. Probable Cause / Recommended Action: Something is blocking the cooling intakes in the system processing unit (SPU). Check for obstructions. The room containing the SPU is too hot. Check for problems with the room air conditioning. Additional Event Data: System IP Address...: 000.000.000.000 Event Id............: 0x443037bc00000000 Monitor Version.....: B.01.00 Event Class.........: System Client Configuration File...........: /var/stm/config/tools/monitor/default_dm_core_hw.clcfg Client Configuration File Version...: A.01.00 Qualification criteria met. Number of events..: 1 Associated OS error log entry id(s): 0x443037bc00000000 Additional System Data: System Model Number.............: 9000/800/L2000-44 OS Version......................: B.11.11 STM Version.....................: A.38.00 EMS Version.....................: A.03.20 Latest information on this event: http://docs.hp.com/hpux/content/hard...core_hw.htm#33 v-v-v-v-v-v-v-v-v-v-v-v-v D E T A I L S v-v-v-v-v-v-v-v-v-v-v-v-v Ok now problem is cleared but this event is still shown... there's a way to clear it? Thanks Stefano |
| |||
| on Fri, 14 Apr 2006 07:22:11 GMT, message id <pan.2006.04.14.07.22.11.85835 @#NOSPAMME#3000.it> came forth, causing the following to be poasted in: comp.sys.hp.hpux Ste (stefano@#NOSPAMME#3000.it) sez: >Hello all, > >so I've an L2000 server with HP-UX 11.... some days ago I got a >temperature problem. System shown me: > >#:/opt/resmon/bin/resdata -R 200802305 -r "/system/events/core_hw/core_hw" -a > >CURRENT MONITOR DATA: > >Event Time..........: Sun Apr 2 22:44:44 2006 >Severity............: CRITICAL >Monitor.............: dm_core_hw >Event #.............: 33 >System..............: mysystem.my > >Summary: >Processor cabinet intake temperature is too hot > > >Description of Error: > > The system intake temperature is too high. > >Probable Cause / Recommended Action: > > Something is blocking the cooling intakes in the system processing unit > (SPU). > Check for obstructions. > > The room containing the SPU is too hot. > Check for problems with the room air conditioning. > >Additional Event Data: > System IP Address...: 000.000.000.000 > Event Id............: 0x443037bc00000000 > Monitor Version.....: B.01.00 > Event Class.........: System > Client Configuration File...........: > /var/stm/config/tools/monitor/default_dm_core_hw.clcfg > Client Configuration File Version...: A.01.00 > Qualification criteria met. > Number of events..: 1 > Associated OS error log entry id(s): > 0x443037bc00000000 > Additional System Data: > System Model Number.............: 9000/800/L2000-44 > OS Version......................: B.11.11 > STM Version.....................: A.38.00 > EMS Version.....................: A.03.20 > Latest information on this event: > http://docs.hp.com/hpux/content/hard...core_hw.htm#33 > >v-v-v-v-v-v-v-v-v-v-v-v-v D E T A I L S v-v-v-v-v-v-v-v-v-v-v-v-v > > >Ok now problem is cleared but this event is still shown... there's a way >to clear it? > > >Thanks >Stefano > > Where are you seeing this error that you want to clear it? -- Josh liberalfascist@gmail.com |