This is a discussion on SSRT2439 Rev.10 xdrmem_getbytes() within the HP-UX Operating System forums, part of the Unix Operating Systems category; --> -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 ----------------------------------------------------------------- **REVISED 10** Source: HEWLETT-PACKARD COMPANY SECURITY BULLETIN: HPSBUX0303-252 Originally issued: 19 March ...
| |||||||
| FAQ | Members List | Calendar | Search | Today's Posts | Mark Forums Read |
| ||||
| -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 ----------------------------------------------------------------- **REVISED 10** Source: HEWLETT-PACKARD COMPANY SECURITY BULLETIN: HPSBUX0303-252 Originally issued: 19 March 2003 Last revised: 11 January 2004 SSRT2439 Rev.10 xdrmem_getbytes() ----------------------------------------------------------------- NOTICE: There are no restrictions for distribution of this Bulletin provided that it remains complete and intact. The information in the following Security Bulletin should be acted upon as soon as possible. Hewlett-Packard Company will not be liable for any consequences to any customer resulting from customer's failure to fully implement instructions in this Security Bulletin as soon as possible. ----------------------------------------------------------------- PROBLEM: Potential buffer overflow in xdrmem_getbytes() and related functions. IMPACT: Potential unauthorized access, denial of service. PLATFORM: HP-UX B.10.20, B.11.00, B.11.04, B.11.11, and B.11.22 SOLUTION: Install the appropriate patches. B.10.20 - PHCO_26158 B.11.00 - PHNE_28982 B.11.00 - PHCO_28480 B.11.11 - PHNE_28983 B.11.11 - PHCO_28481 --> B.11.22 - PHNE_29449 MANUAL ACTIONS: Yes - NonUpdate B.11.04, B.11.22: Download and install the appropriate files. AVAILABILITY: Patches are available now for all except B.11.04 and B.11.22 (libc.1). CHANGE SUMMARY: Rev.01 - Corrected instructions for replacing libc.1 on 11.00 and 11.11. Added CERT CA-2003-10 reference. Rev.02 - Corrected instructions 10.20 Rev.03 - Patches are available for 11.00 and 11.11 libc.1 must still be manually installed for 11.00 and 11.11 Rev.04 - Corrected 11.00 and 11.11 patch information. Rev.05 - Added note about general release patches Rev.06 - Added PHCO_26158. Added AFFECTED VERSIONS section. Rev.07 - Added PHCO_28982 and PHCO_28983. Rev.08 - Corrected patch names. PHCO_28982 should be PHNE_28982. PHCO_28983 should be PHNE_28983. Rev.09 - Added PHCO_28480 and PHCO_28481. Rev.10 - Added PHNE_29449. ----------------------------------------------------------------- A. Background There are potential buffer overflows in xdrmem_getbytes() and related functions. This issue has been reported by CERT/CC in advisory CA-2003-10. HP Tru64 UNIX/TruCluster Servers: The following potential security vulnerability has been identified or reported in the HP Tru64 UNIX operating system that may result in unauthorized Privileged Access or a Denial of Service (DoS). This potential vulnerability may be in the form of Local and Remote security domain risks. Cross reference: SSRT2322, SSRT2384, SSRT2341, SSRT2439, SSRT2412 Not Impacted: HP NonStop Servers HP OpenVMS **REVISED 10** AFFECTED VERSIONS The following is a list by HP-UX revision of affected filesets and the fileset revision or patch containing the fix. To determine if a system has an affected version, search the output of "swlist -a revision -l fileset" for an affected fileset, then determine if a fixed revision or the applicable patch is installed. HP-UX B.11.22 ============= NFS.NFS-64SLIB NFS.NFS-SHLIBS --> fix: PHNE_29449 or subsequent OS-Core.CORE2-SHLIBS fix: libc.1 HP-UX B.11.11 ============= NFS.NFS-64SLIB NFS.NFS-SHLIBS fix: PHNE_28983 or subsequent OS-Core.CORE-SHLIBS fix: PHCO_28481 or subsequent HP-UX B.11.04 ============= NFS.NFS-64SLIB fix: libnsl.1.64_11.00, libnsl.a.64_11.00 NFS.NFS-SHLIBS fix: libnsl.1.32_11.00, libnsl.a.32_11.00 OS-Core.CORE-SHLIBS fix: libc.1 HP-UX B.11.00 ============= NFS.NFS-64SLIB NFS.NFS-SHLIBS fix: PHNE_28982 or subsequent OS-Core.CORE-SHLIBS fix: PHCO_28480 or subsequent HP-UX B.10.20 ============= OS-Core.CORE-SHLIBS fix: PHCO_26158 or subsequent END AFFECTED VERSIONS B. Recommended solution **REVISED 10** Note: If the preliminary patches, PHNE_28929.depot or PHNE_28930.depot have been installed, they must be removed with swremove before installing the general release patches PHNE_28982 (11.00) or PHNE_28983 (11.11) or subsequent. Remove the preliminary patches with swremove if they are on the system: PHNE_28929.depot #B.11.00 PHNE_28930.depot #B.11.11 Install the appropriate patches. B.10.20 - PHCO_26158 B.11.00 - PHNE_28982 B.11.00 - PHCO_28480 B.11.11 - PHNE_28983 B.11.11 - PHCO_28481 --> B.11.22 - PHNE_29449 --> In addition download and install the appropriate --> library files for B.11.04 and B.11.22 as described --> below. System: hprc.external.hp.com (192.170.19.51) Login: xdr2 Password: xdr2 Browser ftp access: ftp://xdr2:xdr2@hprc.external.hp.com/ or ftp://xdr2:xdr2@192.170.19.51/ Note: There is an ftp defect in IE5 that may result in a browser hang. To work around this: Select Tools -> Internet Options -> Advanced Un-check the option: [ ] Enable folder view for FTP sites If you wish to verify the md5 sum please refer to: HPSBUX9408-016 Patch sums and the MD5 program Download the appropriate files and unpack with gunzip: libc.1.gz # B.11.04, B.11.22 libnsl.1.32_11.00.gz # B.11.04 libnsl.a.32_11.00.gz # B.11.04 libnsl.1.64_11.00.gz # B.11.04 libnsl.a.64_11.00.gz # B.11.04 Verify the cksum or md5. If you wish to verify the md5 sum please refer to: HPSBUX9408-016 Patch sums and the MD5 program cksum: 3108550729 1867776 libc.1 2543748420 679936 libnsl.1.32_11.00 3883898582 652664 libnsl.1.64_11.00 2393869471 818268 libnsl.a.32_11.00 205723668 1456024 libnsl.a.64_11.00 MD5 (libc.1) = 118ce482dbb3982b7484ddc434d77a51 MD5 (libnsl.1.32_11.00) = a6bbfcae4a7044b0d1e9aece871c126e MD5 (libnsl.1.64_11.00) = b3c76866d75a4216be7787f219c051df MD5 (libnsl.a.32_11.00) = 1c0aea725173673eb1c8e9410180096c MD5 (libnsl.a.64_11.00) = 06c8fd367c7620a017e9bb2e7df3ec7d For B.11.04 ==================================== #DIR=[path to new files] #cd /usr/lib #cp $DIR/libnsl.1.32_11.00 libnsl.1.new #cp $DIR/libnsl.a.32_11.00 libnsl.a.new #cp $DIR/libc.1 libc.1.new #chmod 555 libnsl.1.new #chmod 444 libnsl.a.new #chmod 555 libc.1.new #chown bin:bin libnsl.1.new #chown bin:bin libnsl.a.new #chown bin:bin libc.1.new #mv libnsl.1 libnsl.1.orig #mv libnsl.a libnsl.a.orig #mv libc.1 libc.1.orig #mv libnsl.1.new libnsl.1 #mv libnsl.a.new libnsl.a #mv libc.1.new libc.1 #cd /usr/lib/pa20_64 #cp $DIR/libnsl.1.64_11.00 libnsl.1.new #cp $DIR/libnsl.a.64_11.00 libnsl.a.new #chmod 555 libnsl.1.new #chmod 444 libnsl.a.new #chown bin:bin libnsl.1.new #chown bin:bin libnsl.a.new #mv libnsl.1 libnsl.1.orig #mv libnsl.a libnsl.a.orig #mv libnsl.1.new libnsl.1 #mv libnsl.a.new libnsl.a After this, any applications that use libnsl.1 must be restarted. Any applications that use libnsl.a must be relinked and restarted. Any applications that use libc.1 must be restarted. Rebooting is the recommended way to restart the applications using libnsl.1 or libc.1. For B.11.22 ==================================== --> Install PHNE_29449 or subsequent and: #DIR=[path to new files] #cd /usr/lib #cp $DIR/libc.1 libc.1.new #chmod 555 libc.1.new #chown bin:bin libc.1.new #mv libc.1 libc.1.orig #mv libc.1.new libc.1 After this, any applications that use libnsl.so.1 must be restarted. Rebooting is the recommended way to restart the applications using libnsl.1 or libc.1. C. To subscribe to automatically receive future NEW HP Security Bulletins from the HP IT Resource Center via electronic mail, do the following: Use your browser to get to the HP IT Resource Center page at: http://itrc.hp.com Use the 'Login' tab at the left side of the screen to login using your ID and password. Use your existing login or the "Register" button at the left to create a login, in order to gain access to many areas of the ITRC. Remember to save the User ID assigned to you, and your password. In the left most frame select "Maintenance and Support". Under the "Notifications" section (near the bottom of the page), select "Support Information Digests". To -subscribe- to future HP Security Bulletins or other Technical Digests, click the check box (in the left column) for the appropriate digest and then click the "Update Subscriptions" button at the bottom of the page. or To -review- bulletins already released, select the link (in the middle column) for the appropriate digest. NOTE: Using your itrc account security bulletins can be found here: http://itrc.hp.com/cki/bin/doc.pl/sc...curityBulletin To -gain access- to the Security Patch Matrix, select the link for "The Security Bulletins Archive". (near the bottom of the page) Once in the archive the third link is to the current Security Patch Matrix. Updated daily, this matrix categorizes security patches by platform/OS release, and by bulletin topic. Security Patch Check completely automates the process of reviewing the patch matrix for 11.XX systems. Please note that installing the patches listed in the Security Patch Matrix will completely implement a security bulletin _only_ if the MANUAL ACTIONS field specifies "No." The Security Patch Check tool can verify that a security bulletin has been implemented on HP-UX 11.XX systems providing that the fix is completely implemented in a patch with no manual actions required. The Security Patch Check tool cannot verify fixes implemented via a product upgrade. For information on the Security Patch Check tool, see: http://www.software.hp.com/cgi-bin/s...arser.cgi/cgi/ displayProductInfo.pl?productNumber=B6834AA The security patch matrix is also available via anonymous ftp: ftp://ftp.itrc.hp.com/export/patches..._patch_matrix/ On the "Support Information Digest Main" page: click on the "HP Security Bulletin Archive". The PGP key used to sign this bulletin is available from several PGP Public Key servers. The key identification information is: 2D2A7D59 HP Security Response Team (Security Bulletin signing only) <security-alert@hp.com> Fingerprint = 6002 6019 BFC1 BC62 F079 862E E01F 3AFC 2D2A 7D59 If you have problems locating the key please write to security-alert@hp.com. Please note that this key is for signing bulletins only and is not the key returned by sending 'get key' to security-alert@hp.com. D. To report new security vulnerabilities, send email to security-alert@hp.com Please encrypt any exploit information using the security-alert PGP key, available from your local key server, or by sending a message with a -subject- (not body) of 'get key' (no quotes) to security-alert@hp.com. ----------------------------------------------------------------- (c)Copyright 2004 Hewlett-Packard Company Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is subject to change without notice. Hewlett-Packard Company and the names of HP products referenced herein are trademarks and/or service marks of Hewlett-Packard Company. Other product and company names mentioned herein may be trademarks and/or service marks of their respective owners. __________________________________________________ ______________ -----BEGIN PGP SIGNATURE----- Version: PGP 8.0.2 iQA/AwUBQAHHT+AfOvwtKn1ZEQIf/wCg/gpInpjc4AcmWDMoT32S+dV8iPsAoNUf XuAwHrobTHQyE2nDXn4TfKU3 =LAT8 -----END PGP SIGNATURE----- -- Yours truly, HP S/W Security Team WTEC Cupertino, California Return-Path: secure@cup.hp.com Reply-to: security-alert@hp.com |